Table 4-9 Technical specifications of the S380-L4P1T

Item Specification
Dimensions without packaging (H x W x D) [mm(in.)]

Basic dimensions (excluding the parts protruding from the body): 35.0 mm x 210.0 mm x 130.0 mm (1.38 in. x 8.27 in. x 5.12 in.)

Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 35.0 mm x 210.0 mm x 136.3 mm (1.38 in. x 8.27 in. x 5.37 in.)

Dimensions with packaging (H x W x D) [mm(in.)] 90.0 mm x 285.0 mm x 180.0 mm (3.54 in. x 11.22 in. x 7.09 in.)
Chassis height [U] 0.8 U
Weight without packaging [kg(lb)] 0.9 kg (1.98 lb)
Weight with packaging [kg(lb)] 1.1 kg (2.43 lb)
Typical power consumption [W] 7.19 W
Typical heat dissipation [BTU/hour] 24.5 BTU/hour
Maximum power consumption [W] 61.65 W (PoE: 50 W)
Maximum heat dissipation [BTU/hour] 210.4 BTU/hour
Static power consumption [W] 4.54 W
MTBF [year] 75.89 year
MTTR [hour] 2 hour
Availability >0.99999
Noise at normal temperature (acoustic power) [dB(A)] Noise-free (no fans), < 30
Noise at normal temperature (acoustic pressure) [dB(A)] Noise-free (no fans), < 20
Number of card slots 0
Number of power slots 0
Number of fans modules 0
Redundant power supply Not supported
Long-term operating temperature [°C(°F)] 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.)
Restriction on the operating temperature variation rate [°C(°F)] When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
Storage temperature [°C(°F)] –40°C to +70°C (–40°F to +158°F)
Long-term operating relative humidity [RH] 5% RH to 95% RH (non-condensing)
Long-term operating altitude [m(ft.)] 0–5000 m (0–16404 ft.)
Storage altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Power supply mode Power adapter
Rated input voltage [V]

Power adapter input: 100–240 V AC; 50/60 Hz

Power adapter output: 56 V DC

Input voltage range [V] Power adapter input: 90–290 V AC; 47–63 Hz
Maximum input current [A] 1.07 A
Memory DDR4: 512 MB
Flash memory NAND Flash: 512 MB
Storage -
Console port Not supported
Eth Management port LAN port
USB Not supported
RTC Not supported
RPS input Not supported
Service port surge protection [kV] Common mode: ±4 kV
Power supply surge protection [kV] Power adapter: ±6 kV in differential mode and ±6 kV in common mode
Types of fans None
Heat dissipation mode Natural heat dissipation
Airflow direction -
PoE Supported
Certification

EMC certification

Safety certification

Manufacturing certification